1.2 Technical Characteristics
TABLE 1.0 2015-25 Upconverter Specifications*
Input Characteristics
Impedance/Return Loss 75 /18 dB
Frequency 70 ± 18 MHZ
Input Level -40 to -10 dBm
Output Characteristics
Impedance/Return Loss 50 /12 dB
Frequency 2000 to 2500 MHz
Output level 0 to -20 dBm
Output 1 dB compression +5 dBm
Channel Characteristics
Gain range (adjustable) -10 to +30.0 dB
Spurious Response <-45 dBC
Frequency Response ± 1.5 dB, 2000 - 2500 MHz; ± 1.0 dB, 36 MHz BW
Group Delay, max. 0.01 ns/MHz
2
parabolic; 0.03 ns/MHz linear; 1 ns ripple
Frequency Sense Non-inverting
Synthesizer Characteristics
Frequency Accuracy ± 1.0 ppm internal ref (± 0.01 ppm, option H)
Frequency Step 1.0 MHz (0.5 MHz, option 5; 125 kHz, option X)
10 MHz Level (In/Out) +3 dBm ± 3 dB (option E)
-105-95-80-70-70
1MHz100kHz10kHz1kHz100 Hz
dBC/Hz
Phase Noise
@
Fre
q
Controls, Indicators
Frequency Selection Direct readout LCD; pushbutton switches or remote selection
Gain Selection Direct readout LCD; pushbutton switches or remote selection
Power Green LED
Alarm Red LED
Remote Yellow LED; RS232C, 9600 baud (RS485, option Q)
Mute Yellow LED
Other
RF Connector BNC (female), 50
IF Connector BNC (female), 75
Ext 10 MHz BNC (female), 50/75 (option E)
Connector, Alarm, Remote DB9 - NO or NC contact closure on Alarm
Size 19 inch, 1RU standard chassis 1.75” high X 16.0” deep
Power 100-240 ±10% VAC, 47-63 Hz, 45 watts max.
Options
Available Options E - External 10 MHz ref input & output
H - High Stability (±0.01ppm) Internal Ref
Q - RS485 Remote Interface
Z - Attenuator 0.1dB steps on Upconverter, -5 - 0.5 MHz Frequency Steps
Connectors/Impedance:
B - 75 BNC (RF), 75 BNC (IF)
D - 50 BNC (RF), 50 BNC (IF)
N - 50 N-type (RF), 75 BNC (IF)
M - 50 N-type (RF), 50 BNC (IF)
*+10˚C to +40˚C; Specifications subject to change without notice.