Cross Technologies 2017-14 Bedienerhandbuch

Stöbern Sie online oder laden Sie Bedienerhandbuch nach Nein Cross Technologies 2017-14 herunter. Cross Technologies 2017-14 Instruction manual Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 21
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 0
Instruction Manual
Model 2017-14
UHF, L-Band, Up/Downconverter
January 2013, Rev. 0
MENU
EXECUTE
MODEL 2017
CROSS TECHNOLOGIES INC.
U U > L G = 10.0
D L > U G = 25.0 INT
MUTE
UPCONVERTERDOWNCONVERTER
REMOTEALARM POWER ALARM
UP/DOWNCONVERTER
RF MONITOR
--------- UPCONV--------
RF MONITOR
------- DNCONV--------
Data, drawings, and other material contained herein are proprietary to Cross Technologies, Inc., but may be
reproduced or duplicated without the prior permission of Cross Technologies, Inc. for purposes of operating
the equipment. Printed in USA.
When ordering parts from Cross Technologies, Inc., be sure to include the equipment model number,
equipment serial number, and a description of the part.
CROSS TECHNOLOGIES, INC.
6170 Shiloh Road
Alpharetta, Georgia 30005
(770) 886-8005
FAX (770) 886-7964
Toll Free 888-900-5588
WEB www.crosstechnologies.com
Seitenansicht 0
1 2 3 4 5 6 ... 20 21

Inhaltsverzeichnis

Seite 1 - Model 2017-14

Instruction Manual Model 2017-14 UHF, L-Band, Up/DownconverterJanuary 2013, Rev. 0MENUEXECUTEMODEL 2017CROSS TECHNOLOG

Seite 2

2.0 Installation2.1 MechanicalThe 2017-14 consists of one RF/Controller PCB housed in a 1 RU (1 3/4 inch high) by 16 inch deep chassis. A switching,

Seite 3 - U > L Upconverter

2.2 Rear Panel Input/Output Signals and Control - Figure 2.2 shows the input and output connectors on the rear panel.ACGNDJ18J2RF IN 10 MHZ REFOUTPUT

Seite 4

Tables 2.1 & 2.2 shows the input and output connectors on the rear panel.TABLE 2.1 JJ10 2.1 J10 Pinouts (RS-232C/422/485*)Pin Function1 Rx-2 Rx+ (

Seite 5

2.3 Front Panel Controls and Indicators - The following are the front panel controls and indicators.MENUEXECUTEU U > L G = 10.0MUTE REMOTEALAR

Seite 6

2.4 Installation / Operation2.4.1 Installing and Operating the 2017-14, Upconverter Section1.) Connect a -40 dBm to -25 dBm signal to IF In, J4 (F

Seite 7 - B) Status Requests

Once the external 10 MHz reference is restored (on J13), the user must again manually (via the front panel LCD or Remote M&C) reselect External Re

Seite 8

2.5 Menu Settings2.5.1 Functions - This section describes operation of the front panel controls. There are three operator switches, the LCD display

Seite 9

2.5.2 Power-On SettingsNOTE: THE LAST STATUS OF A UNIT IS RETAINED EVEN WHEN POWER IS REMOVED. WHEN POWER IS RESTORED, THE UNIT WILL RETURN TO IT&a

Seite 10

2.5.4 Gain ChangesWhen you get to this menu note that the gain changes will be made as you make them but if you do not wish to save the changes you h

Seite 11

2.5.4.2 Downconverter GainTo set the Downconverter gain, first push the Menu/Execute switch to get to the gain setting:Operate the Menu/Execute switc

Seite 12 - *Remote Serial Interface

INSTRUCTION MANUALMODEL 2017-14 UHF, L-Band, Up/Downconverter TABLE OF CONTENTS PAGEWarranty 21.0 General 31.1 Equipment Description 31.2

Seite 13 - CROSS TECHNOLOGIES, INC

ON POWER UPNORMAL DISPLAYPUSHING MENU/EXECUTE SEQUENCEREV 1.00U U > L G = 10.0D L > U G = 25.0 INTPUSH BUTTONPower UpNormal Display

Seite 14

CROSS TECHNOLOGIES, INC.6170 Shiloh RoadAlpharetta, Georgia 30005(770) 886-8005FAX (770) 886-7964Toll Free 888-900-5588WEB www.crosstechnologies.com E

Seite 15 - SPARE FUSE

MODEL 2017-14 UHF, L-Band, Up/Downconverter1.0 General1.1 Equipment Description The 2017-14 UHF, L-band Up/Downconverter converts 0.2-0.4 GHz to 1.2

Seite 16

2017-14 Manual, Rev. 0 Page 4 01/31/131.2 Technical Characteristics Synthesizer Characteristics NONE, Fixed Freque

Seite 17 - U U > L G=+10.0

1.2 Technical Characteristics continued... ©

Seite 18

1.3 Monitor and Control InterfaceA) Remote serial interfaceProtocol: RS-232C, 9600 baud rate, no parity, 8 data bits, 1 start bit, and 1 stop bit.

Seite 19

B) Status Requests Table 1.1 lists the status requests for the 2017-14 and briefly describes them.* PLEASE NOTE: The two character {aa}(00-31) prefix,

Seite 20

C) Commands Table 1.2 lists the commands for the 2017-14 and briefly describes them. After a command is sent the 2017-14 sends a return “>” indic

Seite 21

1.4 Environmental Use InformationA. Rack-Mounting - To mount this equipment in a rack, please refer to the installation instructions located in the u

Kommentare zu diesen Handbüchern

Keine Kommentare