Instruction Manual
Model 2017-03A
Up/Downconverter
October 2013, Rev. H
MENU
EXECUTE
MODEL 2017
CROSS TECHNOLOGIES INC.
U F=1525 G=+00
D F=1525 G=+25
MUTE
UPCONVERTERDOWNCONVERTER
REMOTEALARM POWER ALARM
UP/DOWNCONVERTER
Data, drawings, and other material contained herein are proprietary to Cross Technologies, Inc., but may be
reproduced or duplicated without the prior permission of Cross Technologies, Inc. for purposes of operating
the equipment.
When ordering parts from Cross Technologies, Inc., be sure to include the equipment model number,
equipment serial number, and a description of the part.
CROSS TECHNOLOGIES, INC.
6170 Shiloh Road
Alpharetta, Georgia 30005
(770) 886-8005
FAX (770) 886-7964
Toll Free 888-900-5588
WEB www.crosstechnologies.com
Seitenansicht 0
1 2 3 4 5 6 ... 20 21

Inhaltsverzeichnis

Seite 1 - Model 2017-03A

Instruction Manual Model 2017-03A Up/DownconverterOctober 2013, Rev. HMENUEXECUTEMODEL 2017CROSS TECHNOLOGIES INC.U F=15

Seite 2

2.2 Rear Panel Input/Output Signals and Control - Figure 2.2 shows the input and output connectors on the rear panel.ACGNDJ18J2RF IN10 MHZ REFOUTPUTA

Seite 3 - REAR PANEL

Tables 2.1 & 2.2 shows the input and output connectors on the rear panel.TABLE 2.1 JJ10 2.1 J10 Pinouts (RS-232C/422/485*)Pin Function1 Rx-2 Rx+ (

Seite 4

2.3 Front Panel Controls and Indicators - The following are the front panel controls and indicators.MENUEXECUTEU F=1525 G=+00MUTE REMOTEALARM POW

Seite 5

2.4 Installation / Operation2.4.1 Installing and Operating the 2017-03A, Upconverter Section1.) Connect a -40 dBm to -10 dBm signal to IF In, J4 (F

Seite 6 - C) Commands

AC Fuse - 2 amp slow blow (Type T), 5 mm X 20 mmFUSE DRAWERSPARE FUSE~INPUT100-240± 10%VAC47-63 Hz2A MAXFUSETYPE T 2A GDC250 VOLTFOR 100 - 240 V~~F

Seite 7

2.5 Menu Settings2.5.1 Functions - This section describes operation of the front panel controls. There are three operator switches, the LCD display

Seite 8

2.5.2 Power-On SettingsNOTE: THE LAST STATUS OF A UNIT IS RETAINED EVEN WHEN POWER IS REMOVED. WHEN POWER IS RESTORED, THE UNIT WILL RETURN TO IT&a

Seite 9

2.5.4 Frequency ChangesAt any time during the modification process, if you have made a mistake and do not wish to save the changes you have made, d

Seite 10

2.5.5 Gain/Level ChangesWhen you get to this menu note that the gain changes will be made as you make them but if you do not wish to save the changes

Seite 11

2.5.5.2 Downconverter GainTo set the downconverter gain, first push the Menu/Execute switch to get to the gain setting:Operate the Menu/Execute switc

Seite 12 - D F=1525 G=+25

INSTRUCTION MANUALMODEL 2017-03A Up/Downconverter TABLE OF CONTENTS PAGEWarranty 21.0 General 31.1 Equipment Description 31.2 Technical Ch

Seite 13

ON POWER UPNORMAL DISPLAYPUSHING MENU/EXECUTE SEQUENCEREV 1.00U F = 1450 G = +00.0D F = 1350 G = +25.0UP F = 1450SCROLL <>SCROLL PUS

Seite 14 - SPARE FUSE

CROSS TECHNOLOGIES, INC.6170 Shiloh RoadAlpharetta, Georgia 30005(770) 886-8005FAX (770) 886-7964Toll Free 888-900-5588WEB www.crosstechnologies.com E

Seite 15

MODEL 2017-03A Up/Downconverter1.0 General1.1 Equipment Description The 2017-03A L-band Up/Downconverter converts 70 MHz to 950-1525 MHz (Up) and 95

Seite 16 - U F=1350 G=+00.0

1.2 Technical CharacteristicsTABLE 1.0 2017-03A Up/Downconverter Specifications*---UPCONVERTER---Input Characteristics (IF)Impedance/Return Loss 7

Seite 17

1.3 Monitor and Control InterfaceA) Remote Serial Interface Protocol: RS-232C, 9600 baud rate, no parity, 8 data bits, 1 start bit, and 1 stop bit.

Seite 18

B) Status Requests Table 1.1 lists the status requests for the 2017-03A and briefly describes them.* PLEASE NOTE: The two character {aa}(00-31) prefix

Seite 19

Table 1.2 lists the commands for the 2017-03A and briefly describes them. After a command is sent the 2017-03A sends a return “>” indicating the co

Seite 20 - (option -E)

1.4 Environmental Use InformationA. Elevated operating ambient temperature - if installed in a closed or multi-unit rack assembly, the operating ambi

Seite 21 - CROSS TECHNOLOGIES, INC

2.0 Installation2.1 Mechanical - The 2017-03A consists of one RF/Controller PCB housed in a 1 RU (1 3/4 inch high) by 16 inch deep chassis. A switch