B) Status Requests - Table 1.1 lists the status requests for the 2015-25 and briefly describes them.
* PLEASE NOTE: The two character {aa}(00-31) prefix, in the table below,
should be used ONLY when R
S-485, (OPTION-Q), is selected.
Table 1.1 2015-25 Status R
e
equests
Status Requests
Command Syntax* Description
Command Status {aaS1} Returns {aaS1bbbbcccddAM)} where:
• bbbb = Tx frequency (MHz)
4 characters - standard -
(7 characters - Option-X) (5 characters - Option-5)
• Standard 1 dB step format: ccc = Tx gain (-10 to +30)
• Z OPTION (0.1 dB steps): cccc = Tx gain (-100 to +300)
• dd = Tx input level (10 to 40 => -10 to -40)
• A = 0 if no alarm, 1 if summary alarm)
• M = Tx RF Status (1 = Normal, 0 = Muted)
Command Status {aaS2} Returns {S2E} where:
• E = Ext 10MHz Status (1 = on, 0 = off)